欧美日本大码一区二区-精品与欧美交牲久久久久-av无码在线免费观看-国产精品会所一区二区三区

當(dāng)前位置:首頁  >  產(chǎn)品中心  >  專用儀器儀表  >  消解儀  >  NTP1-HPC601煙度計(jì)
型號(hào):NTP1-HPC601

煙度計(jì)

描述:采用分式取樣、柴油機(jī)加速、減速和穩(wěn)速時(shí)均可測(cè)量煙度;
數(shù)據(jù)自動(dòng)線性化處理,可顯示不透光度N、光吸收系數(shù)K和對(duì)應(yīng)濾紙式煙度值SF;

  • 廠商性質(zhì)

    生產(chǎn)廠家
  • 更新時(shí)間

    2024-04-17
  • 訪問量

    520
詳細(xì)介紹
品牌恒奧德
主要能點(diǎn):
     體化結(jié)構(gòu);
      采用分式取樣、柴油機(jī)加速、減速和穩(wěn)速時(shí)均可測(cè)量煙度;
      數(shù)據(jù)自動(dòng)線性化處理,可顯示不透光度N、光吸收系數(shù)K和對(duì)應(yīng)濾紙式煙度值SF;
      亮度數(shù)碼顯示;
      采用“空氣幕”保護(hù)光學(xué)系統(tǒng)免受污染;
      檢測(cè)室自動(dòng)恒溫控制,可防冷凝而影響測(cè)試度; 
      附自動(dòng)時(shí)間顯示,可選配轉(zhuǎn)速測(cè)量和油溫測(cè)量;
      出現(xiàn)故障自動(dòng)診斷顯示所在單元;
      配內(nèi)置打印機(jī)(或數(shù)字RS-232A接口或模擬接口)。
主要參數(shù):

 

 

 
 
 
 
 
 
 
 
 
 
測(cè)量范圍              不透光度N:0~(相當(dāng)煙度值0~10FSN) 
   光吸收系數(shù)K:0~16.06m-1
示值誤差              ≤±2%(測(cè)量值)
穩(wěn)定性                自動(dòng)校零,量矩漂移≤±1%/4h
重復(fù)性                重復(fù)誤差≤±1%
分辨率                0.1%
輸出方式              數(shù)字直讀顯示,可附打印機(jī)打印煙濃度(暗度)zui大值,測(cè)試
                      時(shí)間、日期等。可附接口與計(jì)算機(jī)聯(lián)網(wǎng)
測(cè)量煙度溫度          70℃(自動(dòng)恒溫),當(dāng)溫度誤差≥±10%時(shí),溫度及錯(cuò)誤示
                      燈亮
環(huán)境條件              溫度0~40℃,相對(duì)濕度≤90%
電源                  AC100-240V 50Hz 消耗率150VA
外形尺寸(含支架)    160mm(深)×400mm(寬)×480mm() 
重量                  約8kg
 
Main Features:
Integrated Structural Design
Adopted a triage-type sampling technique, diesel engine acceleration, deceleration, and steady speed can be measured when the smoke
Linear automatic data processing, can be displayed opacity degrees N, light absorption coefficient K and the corresponding value of filter paper-type smoke SF
High-brightness digital display;
Use of "air curtain" technology to protect the optical system from pollution
Automatic detection of room temperature control, anti-condensation can affect the testing accuracy
Automatically attached to the time display, and optional speed measurement and oil temperature measurement
Show where the failure of automatic diagnosis unit;
Equipped with built-in printer (or digital RS-232A interface or analog interface)
 
Main technical parameters:
Test ScopeNo light transmission N:0 (equivalent to smoke value 0 ~ 10FSN)
Light absorption coefficient K0-16 .06 m-1 
Shows the value error
≤ ± 2% (measured value)
Stability
Automatic zero, volume moments drift ≤ ± 1% / 4h
Repeatability
Repeat the error ≤ ± 1%
Resolution
0.1%
Output Mode
Digital direct-reading shows that smoke concentrations can be attached
printer (dark degrees) the maximum test time, date and so on. Can be
attached to interface with the computer network
Measurement of smoke temperature
70 (automatic constant temperature), when
the temperature error of ≥ ± 10%, the temperature and the error
indicator light
Environmental conditions
Temperature 0 ~ 40
, relative humidity ≤ 90%
Power
AC100-240V  50Hz Power consumption 150VA
Dimensions (with stand)
160mm (depth) × 400mm (width) × 480mm (H)
Weight
About 8kg
 